Showing posts with label Batteries. Show all posts
Showing posts with label Batteries. Show all posts

March 3, 2024

Feline Crew Ladder

We love our feline crew.

If they go for a swim while we are at anchor, we want them to be able to self-rescue.

Since our boat has no swim platform, we braided some stiff, old, retired docklines [3/4” 3-strand nylon] into a feline crew ladder- which we always deploy when at anchor. [That crew has no free roaming deck privileges when underway…] 

We left a loop at the top for hanging on a cleat, and clubbed the bottom. It extends about a foot below the water surface, so could never get caught up in the high speed underwater winch, but facilitates use by a swimming gato. 

To introduce it to the crew when it was new, we temporarily fastened it to the mast and anointed it with catnip…






We made this hawse ladder several years ago,  and it has held up well [and thankfully has yet to be used.]

We sometimes spend weeks at a time lying at anchor, so the underwater portion of the rope will invite some growth and creatures. It is easily cleaned when we forget to retrieve it while getting underway, and is ultimately dragged along in the water at 6-8 knots for a while…  

Yes, we are occasionally asked by other boaters [a rare occurrence where we hang out…] what it is for…




January 21, 2020

Lights out...

Under the heading of When Things Go Wrong...  [Or Sh.tuff happens...]
In summer 2018, peacefully at anchor one sunny afternoon, our 12V DC power shut down.
Everything off. 
No sound. No sparks. No smoke. No smell. No alarms. Zippo... Nada...
And no battery power... anywhere...

Ruht Roh...
And no high load before this occurred [just the usual stuff averaging ~12 amps 12V DC…]
It was as though the 350 amp primary feed fuse at the batteries silently blew [which was my first fleeting thought…]
I decided to do some tracing and grabbed a VOM to test for voltage on the [few] 4/0 positive [and negative] cable connections starting at the battery bank.

12.7V DC at the batteries— before and after the 350A fuse [which protects the boat from a direct short in the 4/0 feed from the battery bank.] Good.
Hmmm… the alternator on the engine still has 12.7 volts…   [This also means the high amperage fuse connecting the alternator output to the battery bank isn't blown.] Good.
Next in line is the emergency DC power disconnect switch in the pilothouse. This switch kills all power from the house battery bank to everything on the boat except the engine starter and alternator... so I continued there [after first confirming it had not been accidentally switched off—  by no one in particular...]
OK; 12.7 volts on the input [battery] side of the switch… Good.  
But zero voltage on the output side... Hmmmm?...  Not even a fraction of a volt? 

Not good... [Yup, the switch was on— and cool to the touch…]
Hmmmm?…
I toggled the switch off and on a few [dozen] times [Hoping for what exactly?... To remove corrosion on the contacts? Or toggle contacts fully into position? Or make is magically start working by touching it...?] 

No such luck... No change... Still no battery power.

Apparently the switch just suddenly [and silently] died— and with just the ambient 12V DC load… [e.g., No surge of current from running a welder off the inverter... I exaggerate…]
Having no spare switch onboard [but several in our storage facility...] I ended up just bypassing the switch to put us back online. [Thankfully, the switch was the only culprit— the root cause of this issue.]

This seemed absurd at the time because one never expects a high amperage switch that has maybe been cycled a handful of times in its life to catastrophically fail out of the blue— especially with no appreciable electrical load…
On the plus side, that is the right way to fail… [vs. discovering you cannot disconnect battery power... in an emergency…]

Remember, this is the switch to be quickly turned off in the event the symptoms listed above present themselves... [Smoke, sparks, 'electrical smell', lights dimming and flashing, etc...]
What happened?
After I removed the switch, I noticed one of the 3/8″ cable connection studs on the back was loose; the other wasn’t. I suspect a connection inside the switch [solder/weld?] just suddenly yielded, unceremoniously breaking the circuit. [I didn't care enough to tear it down as it was to be replaced with something different... more below...]
Perhaps the  4/0 cables hanging on it induced a strain that over time broke the bolt’s connection to the switch? [Inadequate strain relief? The cables were firmly secured mere inches from their attachment point on the switch... Perhaps it was over tightened when installed in 1999 by the previous owners? Manufacturing/design defect? Poltergeist? Who knows...?]
But— remember our story started out that it was a warm and sunny afternoon… so it wasn’t all that bad… 
Doesn't Murphy mandate events like this are supposed to happen when it it is pitch black and stormy, the boat is bucking at anchor like a bronco, and you have only been asleep for an hour after a long day, and perhaps you are even coming down with the flu, or are seasick…?  [Oh, and the first 3 flashlights you grab have weak batteries...] Catch my drift?...


Looks like Murphy gave us a pass this time... and...

The dead switch has since been replaced…


The new 300A [continuous; 500A ittermittant] emergency cut-off switch [shown with key removed...]
[Different manufacturer from the one being replaced...]
Our lessons learned include: 
  • Always troubleshoot from the bottom up [To determine the root cause, start with the roots... and don't ignore other possible contributing factors...]
  • Never assume you immediately know what has happened [Don't believe everything you think...]
  • Be prepared for any component to fail without warning or apparent cause at any time [AKA Cruising...]

Are there any proactive measures or any preventative maintenance to help mitigate something like this from re-occurring?  
Search me... Leave a comment... I'm all ears...

This post began life as my reply to the question:
"What’s the most ridiculous repair you’ve done on your boat?"  
[Asked by our friends on SV Galapagos in their We're in Hot Water post;  7-Mar-2019]

February 18, 2019

Tidbit: Solar Panels in mid and high latitudes [AKA DC Power Management...] [Updated Aug-2023]

This is one of a series of brief, no nonsense posts that we call aTidbit:
noun; small and [possibly] particularly interesting item of gossip or information...
The purpose is to share succinct posts about lessons learned, or things we use or do that work [or don't...] that are common to most of us boaters. 

The goal is to garner feedback from those of you having first-hand experience with a different approach/ solution/ product/ or additional useful information to share...  
We never assume what we are sharing is the ideal or only; it just seems to best suit our needs [and/or habits and/or budget] from our experiences thus far...
Sometimes these Tidbits originate from a topic of discussion on one of the forums we participate in, and this happens to be one: Link to original thread [30-Dec-2018]

Since we are asked this question often, it made sense to post a more detailed response.

                  ➛ ➛ Peruse the right-hand sidebar for the up-to-date list of Tidbits ➛ ➛                  


Original Question from Cruiser's Forum:

Re: Solar panel output high latitudes?

Quote:
Originally Posted by sailingrock View Post
Above 50 degrees latitude, what kind of output will solar panels produce in the real world. "Real world" as in typical weather conditions?

...

My response:

Following are two real world solar panel installations which include accurate data gathered a bit further north of 50°—  on the E Pacific side of things... 
Note: I'll provide electrical data in watts [other values listed are nominal...] so you can crunch the numbers to derive your own conclusions and decisions based upon your individual electrical system and requirements... 
Also note that climate is likely as much, if not more of a factor than latitude [addressed below...]

If you need a math refresher: [within the context of this post...]
Watts [W] / Volts [V] = Amps [A]  Power
Watt-Hours [Wh] / Volts DC [V] = Amp-Hours [Ah (at specified voltage)] Energy
1 Kilowatt-Hour [kWh] = 1,000 Watt-Hours 

 

Here are three handy online calculators:   

     

Background and reference:

We live onboard our boat fulltime, and are away from the dock [cruising and anchoring] ~9+ months each year.

Denali Rose's house battery bank capacity is ~10.8 kWh [~10,800 Wh, or ~900 Ah @ 12V DC (nominal) flooded lead-acid (FLA) batteries...]

Our average daily [24hr] energy consumption [averaged annually] is ~2.2 kWh [~183 Ah]. This includes running 2 refrigerators and 1 freezer full time, a variety of LED lights, computers and related devices, inverter for AC, the Espar diesel heater and ship's electronics much of the time... 

Our 12V DC charging sources include:
  • Battery chargers powered by either shorepower or an onboard 10 kW AC generator [2.2 kW combined capacity, all programmable]
  • Alternator on the engine [1.4 kW with programmable external regulator]
  • Solar panels [3 totaling 460 W; each with its own programmable MPPT controller]
  • KISS wind generator [300 W]


First mid latitude solar panel example: [SV Denali Rose]

We cruised between 55° and 59° N along the SE coast [Inside Passage] of Alaska during 2018. 

The 3 solar panels [460 W combined] on our boat each have their own Victron MPPT 75/15 controller. This not only helps mitigate [isolate] the affects of partial shading [i.e., loss of output] of a single panel, but also provides redundancy [two panels could share one controller if one became inoperative. 
Here is a simplistic but effective demonstration of the effects of partial shading, and also compares series to parallel wiring of solar panels.
Our 3 controllers share one battery voltage/temp sensor installed on the house bank, and are the sources of the solar output data in the 1st example, below. 
It is worth noting that in our current latitudes, our house bank rarely achieves 100% state-of-charge [SOC] when we are not on shorepower. Therefore, the MPPT solar panel controllers are in a constant Bulk charge state. [i.e., outputting maximum possible into the battery bank when they are active; 100% Bulk duty cycle.] 

The following data is for the calendar year 2018: [Aggregated data for 2019-present on will be published one of these days, but as of Aug-2023 the data still support the same conclusions...]

1) One 130W panel on top of bimini. 
New in 2005; slightly pivotable. More frequent shadowing in this location— mainly from the 2 masts [and occasionally, a crewmember...]
The Victron controller reported it produced a total of 49 kWh in 2018:

You can just see a corner of the solar panel on top of the bimini, and the horizontal tubing it pivots on.
[and our first mate, Gus...]



2) Two 165 W [330 W combined] mounted side-by-side as one assembly on top of davits. 
New in 2017; Pivoting to optimize sun angle. Typically fewer shadows than bimini top location.

These 2- 165 W panels produced a combined 193 kWh in 2018.

Here the panels are temporarily leveled to provide easy access to the ladder on the transom...
Note the shadow [from the mizzen boom..] on the starboard panel. 



What was the approximate solar panel yield on Denali Rose for 2018?

Combined panel energy yield: 
  • ~49 kWh [bimini]+ ~193 kWh [davits] ≈ 242 kWh [total annual yield]
  • 242 kWh [total annual yield] / 2.2 kWh [average daily consumption] ≈ 110 days of electrical consumption coverage from our solar panels

What percentage of our annual energy consumption does this represent?
  • ~2.2 kWh daily consumption x 365 days/yr ≈ 803 kWh/year total consumption
  • ~242 kWh [total solar/yr]  / ~803 kWh [total annual consumption] ≈ 30% of our total 12V DC energy needs were replenished by our solar panels.
Even though this result is a very simplistic average [one that ignores many other variables- including seasons...] it is an indication [for us...] that our solar panels are worthwhile...


Other factors influencing insolation on the boat [besides latitude...]: 

Aside from boat infrastructure shadows [e.g., masts and booms...] on the panels, and weather, we are also subject to geographical factors that affect solar gain on the boat. 

For example, we often anchor in locations surrounded by tall mountains [e.g., 3-7,000 ft]. This often results in shorter periods of direct exposure to the sun in summer, and blocking it completely in winter... [Take another look at the photos above...]

I strongly suspect climatic factors affect insolation even more than latitude. For estimating climate and weather related factors [e.g., solar intensity and exposure periods, and percentages of cloudy days...] I like to use Weatherspark.com and Climate.gov.

We also optimize any potential gain from our solar panels by running the generator early in the morning [i.e., before the sun is intense enough to power the solar panels...] on days when the house bank needs a deep charge. [i.e., is approaching 50% SOC]

The battery chargers will get the bank back to 80+% SOC fairly quickly. The solar panels will continue bulk charging during the sunny portion of the day. [This is less important in winter months when days are short and solar gain is minimal...]


Second high latitude solar panel example: [monthly data from an optimized (auto sun tracking) land based system @ 65° N]

Family members in interior Alaska have 2 large grid-tie auto-tilt/tracking [max possible-output] solar arrays on a mountaintop [i.e., optimized insolation for the location...] 

The 2 multi-panel arrays have a combined capacity of 5.5 kW.





Their data [kWh] follows: [Note the 2nd array went online in 2010...]

Go to live data 


Another personal demonstration of the efficacy of solar panels at mid latitudes:

We also have a truck camper and 2 enclosed trailers stored at 56° N. 

Each has its own 100 W rigid solar panel [3 total; each with their own PMW controller] on an adjustable rooftop mount— which is typically tilted ~55° when stationary for long periods. [This angle also helps shed snow...]

These panels keep their respective 2.4+ kW [200+ Ah 12V DC] battery banks topped up year around: 
The truck and camper each have 2 batteries [4 total] maintained by one 100W panel. 
One of our trailers also has the batteries from our two ATVs tied into that trailer's solar panel circuit with individual DC - DC chargers...



I hope this will help you determine whether solar power is worthwhile for you in the latitudes and climates you are considering.


Related Resources:


_______________________________














PS to SELF: DON'T CHANGE THESE IMAGES AS THEY ARE LINKED TO THE ORIGINAL FORUM RESPONSE...

October 19, 2018

Friday Funny 10-19/18 (What, Where, Why)


Blogging about blogging, I can't wait to see what I'm thinking. 😁

When we first started this journal, we thought this would be a good way for friends, and family to know where we were going, and that we were okay. Yes, I think we are accomplishing that, but it has become much more.

The important part keeps track of our upgrades to the boat, the parts, and pieces, as well as the thought process behind the, what we did, and why we did it. Those are recorded in the right side bar under, Stuff we have, and use, Bill writes those. This column has been useful as an online reference not only for us, but to use as a referral when others ask questions. We're keeping up the tradition of Denali Rose's previous owners, they kept fourteen 3 ring binders of all receipts, documentation, user manuals, boat spares, napkin doodles, and anything related to the boat. It was impressive. Thank you Jack, and Susan, (known as Fred). We still have them, but we don't store them on the boat.



I realize you might think I' referring to Jack, and Fred, I'm not, You can't fix crazy is for Bill, and Donna.

I once read a blog post from someone I respect, and she said she was done with blogging. She said she was bored with it, and also, she was bored with reading sailing blogs. They were always; I went here, saw that, went there, did that, and she was tired of it. I decided that I would try to avoid writing that way, after all, who wants to sit through someone's vacation photos, and their monologue about what they did.

That said, here's what we did. 😉

Gluttons for punishment, we decided to go back down Rocky Pass, and head back to Wrangell. Bad weather rising. 🎶🎵This time the skinniest water level was 7foot. Denali Rose draws 6 1/2, and we measure the water level from the bottom of the keel, so 7 foot under the keel, still a bit close for comfort. We spent a night at anchor at the mouth of the pass, and the next morning headed for the home slip. We had calm seas, some wind on the nose, against the current all the way, and major fog. Yay for radar! It was a 9 hour motor..... Gus was glad to get it over with.

Can't see sh@%.

We're safe and secure in our slip now, awaiting the major rain, and 40-45 knot winds that's been predicted. Frankly I was surprised that it didn't start while we were on the way back in, weather often happens earlier than what is expected. I didn't voice that out loud... no jinxes.

Last night, we were sound asleep, (secure, and listening to the rain on the roof, so soothing), We were startled awake by our new NEST fire/CO2/carbon monoxide monitors, yelling at us that the carbon monoxide levels were at dangerous levels. 

These new smoke alarms have all kinds of great features, they last 10 years, talk instead of alarm, have an app on your phone, more sensitive than conventional, and they communicate with each other. We have 3 of them installed, one forward, mid, and aft.

The Nest in the aft cabin was advising us that there was carbon monoxide in the living room, actually the pilothouse, we have to go with their preprogrammed labels.  Bill went out and opened hatches right away to get clean air before investigating. It was frightening to hear the device saying that the carbon monoxide was at dangerous levels, and the red light pulsing. All is well however, turns out that the house batteries, which were being charged by shore power, were giving off hydrogen, and it was a false positive for carbon monoxide. It's interesting that the conventional smoke alarm in the engine room didn't go off, we have had it do the same thing in the past, but with the hydrogen at much higher levels. 

We do have a fresh air vent into the battery compartment, but we could use some more positive air flow when charging, and equalizing the batteries.

The Nest.
We're going to get some projects done while we are tied to the dock, there's always something to work on. I'm going to get ready for Christmas, yes, it's early. I'm going to get my shopping, my decorating supplies, my wrapping, cards, and ordering done, and loaded on the boat. You'll be happy to know I have a really great gift for Bill, and it's already wrapped and stored. I'm hoping to spend the holidays onboard with Bill this year. (knock on wood) The next time I have the privilege of spending Christmas with my brother, and his family, I want it to be more fun for everyone.




As always, we enjoy hearing from you, either here in comments or on our Facebook Denali Rose Sailboat page.


March 26, 2016

EPIRB Battery Test

Two EPIRBs came with the boat we acquired in May-2014; one was packaged with the life raft and one in mounted just inside the upper companionway. 

When we had our life raft repacked/certified at that same time, we had them remove the out-of-date EPIRB [batteries past their shelf life, and no internal GPS...] and replace it with a much smaller, waterproof, freshly dated [6 year battery shelf life]  PLB with built-in GPS. 

To be prudent, we investigated the cost of replacing the battery in the outdated McMurdo / Pains Wessex SOS Rescue 406 EPIRB that we had removed from the life raft.


 At US$250 plus shipping both ways, we decided to toss it because we can buy a new, modern EPIRB with GPS and a 10 year battery life for about US$100 more than the replacement battery...

This decision left us with an old EPIRB to dispose of. Since there was no USCG base near us at the time, we went online and found the original manual which included disposal instructions. The two options were to either remove the battery and recycle appropriately, or remove the antenna, wrap the unit in metal foil [to prevent signal transmission] and set it off to drain the battery...

We decided to fire off the unit to observe the battery runtime and prevent activation in the future.

This EPIRB had already been declared inactive in the NOAA registration database, but we wanted to make sure and not contribute to the already prevalent false alarms. Therefore we decided to follow the manufacturer's instructions for running the EPIRB without the antenna, but instead of wrapping it in aluminum foil, we put it in our stainless steel oven [solid door; i.e., no glass] and fired it off. [...the EPIRB, not the oven...] 

We started the test at the top of the hour- the designated time period for testing PLB and EPIRBs- just in case...

As you might expect, the xenon [not LED as in more modern EPIRBS; i.e., bigger drain on battery...] strobe started flashing immediately, and the other lights indicated it was faithfully attempting to transmit the emergency signal.  

No phone calls were received, nothing was heard on the VHF radio, and no rescue boats or helicopters showed up so apparently we were successful attenuating the signal. 

Since the unit was 7 1/2 years past the original [5 year shelf life] battery expiration date, we didn't expect it to last for long. Therefore we peeked in the oven every ~4 hours to see if the strobe was still firing and the other lights still indicated it was transmitting... 

These units are specified to meet the EPIRB standards of transmitting for a minimum of 48 hours at -4°F. [The ambient temperature inside the boat averaged 65°F during the testing period.]

We continued checking every few hours [4-6 times each day] and after 4 days the unit was still transmitting. 

It finally died sometime around the 4 1/2 day mark. [~108 hours] We left it in the oven another 24 hours just in case the battery came back to life after a rest... it didn't...

Who cares? Well, we're naturally curious, and we found this test encouraging. 

To summarize: this older model EPIRB [without GPS] with batteries 7 years and 7 months past their expiration date still ran more than twice as long as the minimum required period [48 hours with non-expired batteries...]

What does this mean to us? When the batteries expire in our current and future EPIRBs, we will keep them onboard and actively registered for a couple of additional years as back-ups to their replacement(s). 

This is based upon the assumption that battery technology keeps improving, and if the older lithium batteries delivered the performance documented above, newer battery technology/formulations will likely be equal or better.

Will we bet our lives on it?  Nope! [Nor are we recommending anyone else does either...]

The key word here is back-up; we will always carry at least one in-date, modern EPIRB on the boat, and likewise an EPIRB or PLB packed in with the life raft, and we always have PLBs on our person- on the boat and on land.

That means as of this writing we can fire off 5 NOAA registered emergency beacons in case of an emergency. [Our written plan is to do this in succession- not simultaneously- in extenuating circumstances; possibly using the out-of-date units first if it isn't an abandon ship emergency. If a beacon fails to transmit, then fire off another...] Bump that count to 6 once we replace our current EPIRB later this year... [Update Dec-2016; New 10 year EPIRB added to inventory.]

But we all know SOPs and reality can vary in times of crisis... At least the odds are in our favor that one of these buggers ought to work if/when needed...

Here's hoping none of us ever need to activate our emergency beacons in anger...


Related Resources: 


August 2, 2014

New Batteries (with a built-in watering system!)

This post has been updated and is now redirected to the maintained permanent page in our sidebar under the grouping Stuff we have and use [and do...]

Please go to that page [which was last updated Apr-2017] to see the most recent information, as this post will become out-of-date over time... 


–––––––––––––––––––––––––––––––––

Out-of-date original post follows: [2-Aug-2014] The text is aged parchment color to remind you this is the old version...
Battery: Electrochemical storage device capable of lighting an incandescent lamp of wattage about equal to that of a refrigerator bulb for a period of 15 minutes after having been charged for 2 hours...    (Sailing Pocket Dictionary by Henry Beard & Roy McKie)


This page is now out of date! See the most recent version.

When we were evaluating the boat for purchase, we learned the broker had once forgotten to plug the boat into shore power after moving it to a different dock. This resulted in the battery bank draining completely, killing two of the eight 6 volt Trojan T-105 [lead-acid] batteries [which were ~6 years old...] Instead of replacing all batteries, only those two were replaced (contrary to everything I have ever read, heard, or understood about maintaining battery bank integrity. i.e, all or nothing…)

Therefore I figured we would soon need to replace the entire bank. After cruising a couple of weeks, this became evident; the batteries were barely getting us through the night at only ~120 AH consumption [from a 900AH initial capacity bank.] Due diligence lead me to verify the charging systems were working correctly, and they were. I also equalized and load tested the battery bank the next time we were in a marina with shore power. (Ketchikan, Alaska) My suspicions were confirmed: the bank was down to ~50% of its original capacity. Time to go shopping.

Fortunately the local Crowley fuel depot in Ketchikan is a Trojan dealer and stocked the T105 batteries (and at competitive pricing!) They even agreed to deliver the 8 new batteries [~500 lbs] to the boat, and cart off the old batteries for no charge. Done deal.
Update Aug-2016: I recently learned Trojan has introduced their 'Smart Carbon' technology for their 'RE' [Rural Energy] battery line. And they offer a direct replacement for the T105 battery we are using; the T105RE . These Smart Carbon batteries are purported to tolerate not always reaching a full state of charge better than the standard battery line, yielding a longer useful lifetime. [~15%]
I will be researching this further, and watching for first-hand accounts. In the meantime, were I ordering new batteries today, I would probably go this direction assuming pricing is not out-of-line... 
However, before committing, I needed to decide whether to change over to AGMs ["maintenance free"] or stay with wet cell batteries that require the routine addition of distilled water. This was especially important because the location of all 8 batteries is a vented, custom locker under what remains my tool and spare parts storage area. That means all that heavy stuff needs to be moved and temporarily relocated every time I inspect and water the batteries. 

AGMs offer other advantages as well, but I was most attracted to the “maintenance free” aspect. AGMs also came at a ~50% premium, so I researched ‘remote’ [single point] methods of watering lead-acid wet-cell batteries. That is when I discovered Trojan (and Flow-Rite) offer just such a system for a lot less than the price difference between the battery types (and it will fit future batteries next time they need replacement…) 

Enter the Trojan HydroLink™ Watering System (I chose the Clampless Tubing option…)
[I also investigated the offerings from Flow-Rite but stayed with Trojan in this instance due to the lower profile, seemingly more robust design-including purported spark and flame arresting capability- and availability at the time...]


This page is now out of date! 
See the most recent version.

Trojan HydroLink™ Watering System with clampless tubing
Trojan HydroLink™ Watering System with clampless tubing. (Photo from sales literature.)
The quick-disconnect [with internal check valve] is the large black fitting. The orange rubber caps cover unused connections on the T's, and the T's floating to the sides of the batteries [not on battery caps] must be for illustration purposes since they came pre-installed on the manifolds...
HydroLink components replace the stock single battery caps [3 on a 6 volt battery] with a single cap [manifold] that covers all 3 cells, has a built-in pivoting T fitting for the clampless tubing [which strongly resembles heavy duty 1/4” ID fuel hose…] a visual indicator [fiber optic] of water level, and small float valves in each cell that allows new water in only if below a prescribed level (and acts as a check valve to prevent electrolyte from entering the watering manifold plumbing.) 

The whole job consumed about 4 hours of my time [including polishing the battery and cable terminals.]  The most demanding portion was lifting the old batteries out and carrying them to the dock for pick-up. (Bringing in the new batteries was mostly downhill…)

I re-used the well thought-out 4/0 cables Jack [the previous owner] had fabricated for the last set of batteries, and finished the installation by figuring out the most efficient way to route the rubber Clampless Tubing between batteries. That took all of 5 minutes... [Trojan is a bit stingy with the tubing; I had 6" left over...]

I put the single quick-disconnect [with built-in check valve] for watering all the batteries in the engine room. The Hydrolink kit I purchased came with an outboard motor style fuel bulb with a clear hose with check valve on the intake end (for dropping into a bottle of distilled water) and a quick disconnect fitting mating with the one on the end of the battery watering hose I terminated in the engine room. 

I fully charged the batteries overnight [Trojan warns to only add water to fully charged wet-cell batteries because the liquid level increases slightly as the cells charge...]  The next day, while the batteries were still out in the open, I grabbed a bottle of distilled water and dropped the check valve end of the hand pump into the bottle. I next purged the fill line of air by pumping it until it was full of distilled water (holding the quick disconnect over the jug of distilled water- effectively recycling the water) then attached it to the battery fill quick-disconnect fitting. I squeezed the bulb a few times (~4) until is wouldn’t squeeze any more. I checked for leaks and found none. I squeezed the bulb pretty hard again just to make sure, and all connections remained dry.

Wow. I just watered my 8 new batteries from my engine room in less than 30 seconds- including set-up time. It took longer to put the bottle of distilled water and the pump hose assembly away…



This page is now out of date! 
See the most recent version.


Lessons learned? 



  • Do your own research. The Trojan dealer, while great to work with, admitted no knowledge of remote watering systems. If I hadn't pursued this on my own [and I had no idea if such a system existed at the time...] I wouldn't have discovered these watering systems. 
  • This experience seems to reinforce the all-or-nothing strategy when it comes to replacing weak batteries in a bank.
    • In a pinch [e.g., this happens 'out there' where new batteries are not readily available...] removing the weak battery(ies) (in proper numbers- pairs in this case) would reduce bank capacity but also prevent the weaker batteries from weakening the entire bank.
  • If I could have it would have been great to take delivery of the batteries with the HydroLink manifolds pre-installed instead of having to order the kit from a different supplier and install them myself. While the installation is trivial, they do snap tightly into place giving the impression there is a possibility of breaking a manifold component if you aren't cautious when applying the required pressure.... 
    • Don't take this wrong: the manifolds are very sturdily constructed...
    • On the other hand, perhaps it makes sense to install the manifolds yourself after the batteries are placed into position- eliminating the opportunity to break a manifold while handling the heavy battery.
I can highly recommend this single-point watering system for anyone who desires to use wet-cell lead-acid batteries. [Total cost of the watering system for all 8 batteries was just under US$200 including shipping to Alaska in summer 2014...]



This page is now out of date! 
See the most recent version.


Additional information and resources:



  • Related articles/posts (that we know of) that are worth reading:


Photos of our project:
Dry fit of new Trojan T-105 batteries for Denali Rose's house bank
Looking down into Denali Rose's battery bank right after the new Trojan T-105 batteries were placed into position. [Showing original battery caps.] The HydroLink watering line with the quick disconnect will be lead through the hole the battery cables go through in the upper right of this photo, terminating in the engine room.

Completed installation of new Trojan T-105 batteries for Denali Rose's house bank
Here is the same view showing the finished installation of the HydroLink battery cap replacements plumbed with the small diameter black tubing and red rubber caps on all unused T connections. 


Also showing are the 4/0 battery cables wiring 4 pairs of 6 volt batteries in series (yielding 12 volts DC) and then paralleling those 4 pairs into the 900 amp-hour house bank we enjoy.

Note the through-bolted blocking securing the batteries in place.

All that remains to be done after this photo is to install the top of the battery locker and re-stow the tools and heavy parts boxes on top of it.

I can't figure out why the boat has a slight list to this [port] side... 


This page is now out of date! 