Descaling Engine Heat Exchangers [and other raw water plumbing...]

Is your engine starting to run warmer than usual?

Based upon this descaling article in Practical Sailor, we chose to use CLR (among several tested and rated products) annually to descale the raw water circuits on our propulsion engine and generator (which include several copper-nickle heat exchangers.)  

CLR is also safe to use on the dibghy outboard engine since there is aluminum to be found in its raw water cooling cirsuits.

We chose CLR because it is safer to work with, has no fumes (unlike muriatic acid...) and CLR won't harm any aluminum (or anodes) in the raw water circuit when used as directed in the above article and per manufacturer's instructions. 

CLR is also effective at removing rust stains, cleaning the shower floor and walls, clearing air conditioner/ heat pump raw water circuits, descaling coffee pots, outboard motor cooling circuit, etc., etc. (Everything on a boat should have more than one purpose, right?)

Instead of removing the various heat exchangers and soaking in a bucket, we leave them in place and use a small pump to recirculate 50% diluted CLR (per above linked article) through the raw water coolant loops of the main engine and generator annually.  

If you prefer to purge any raw water from the cooling circuits before descaling, pump some fresh water through first- discharging into the bilge instead of the bucket. Then put your hoses in the bucket of diluted CLR and turn on your recirculation pump.

Recirculating 50% diluted CLR clears the deposits in the raw water side of the heat exchangers. 

Keep it going until the discharge stops foaming.

       
The time elapsed between above photos was ~ 2 hours. (Severe deposits can take hours longer- even overnight...)

The red return line in the above photos is the disconnected exhaust elbow raw water injection hose on our generator (you wouldn't want to hydrolock your engine with the descaling recirculation pump...)

The black hose is the suction hose which normally goes to the raw water through-hull (strainer) for that engine.

 

This is a routine part of our annual maintenance. It also provides an opportunity to inspect the exaust elbow injection site for corrosion since we have to remove that hose to recirculate the descaling solution.


When we are finished with each engine, we dump the bucket of used CLR solution into the bilge with the primary (lowest or maintenance) bilge pump off. (We have several bilge pumps installed- each above the previous- and they are left on, so are covered in an emergency...) 

After adding the 2nd bucket full, we turn on the maintenance bilge pump for a few seconds to fill the discharge hose, and then turn it off again to let everything soak overnight. To empty the CLR from the bilge, capture the bilge pump discharge and dispose of properly. 

Three-way valves strategically placed in the bilge pump discharge and engine raw water hoses mentioned above make this annual maintenance quick and easy with no hoses to remove... (With well planned 3-way valves you could even use the bilge as the bucket, and the maintenance bilge pump to recirculate the descaling mixture...)


Win-Win.

 

______________

Links to related forum discussions:

Nauticat USA Forum 29-Jan-2023 

Cruiser's Forum 27-Jan-2023


May 10, 2019

Tidbit: Fresh water as coolant for air conditioning and refrigeration systems

This is one of a series of brief, no nonsense posts that we call aTidbit:
noun; small and [possibly] particularly interesting item of gossip or information...
The purpose is to share succinct posts about lessons learned, or things we use or do that work [or don't...] that are common to most of us boaters. 
Our goal is to garner feedback from those of you having first-hand experience with a different approach/ solution/ product/ or additional useful information to share...  
We never assume what we are sharing is the ideal or only; it just seems to best suit our needs [and/or habits and/or budget] from our experiences thus far...

                               ➛ ➛ Peruse the right-hand sidebar for the up-to-date list of Tidbits ➛ ➛                               

Many boats have pump driven raw water cooling loops for air conditioners [A/C] and refrigeration systems. 

Water cooling is required on the A/C units when the compressor is runing for either cooling or heating [e.g., reverse cycle heating.] 

Water cooling also boosts the DC powered refrigeration system efficiency [beyond the electric fan most have...] when ambient temps in the compressor location exceed 90°F.

Our 3 air conditioners serve two functions: cooling and heating [using either reverse-cycle heat or resistance coils.] We often use the A/Cs for heat when at the dock in cooler weather. [We are currently at 56°N in SE Alaska.] 

Why use electricity?  Where we are, electricity costs about the same as the amount of diesel we would burn if we used our Espar heater, and this way it keeps the hours off the Espar...

We are lucky in that the Pacific waters usually stay warm enough for reverse-cycle heat to work well. [Water temps needs to be above ~42°F for reverse cycle heat to work well...] Therefore our A/C units also have resistance heat coils as a back-up. [i.e., just like a portable electric heater...] But resistance heating is not as efficient and requires more electricity to produce the same amount of heat as reverse cycle does, so if using electric heat, we prefer running reverse cycle on the A/C compressors...

However, since we also enjoy venturing to higher latitudes with even cooler water temps, we experimented with using a potable water tank for the cooling water loops because the water in those tanks [even though they sit low in the hull...] averages 10-20°F warmer than the water we are floating in; Perfect for using reverse cycle heat in colder waters...

This approach of is not new or unique: The previous owner of our boat did just this with one of the refrigeration water cooling loops. Great idea. Lets extend this to the air conditioners/ heat pumps...

For a couple of years now we have been using one of the boat's potable water tanks for all the cooling water loops— instead of raw water. [Our two potable water tanks— 110 gallons each— are low in the hull, but stay warm enough for efficient reverse-cycle heat— even in freezing water.] We dedicated one tank to this use. It is also still a back-up potable tank if needed...

The cooling plumbing can be easily switched back to raw water again if needed via 3-way valves. [We never intend to switch back to raw water, but can if necessary...] If we switched back and forth, we would have to clean and sanitizing the raw water loop[s] before switching back to potable... [More below...]
We should mention all our drinking water runs through a .5µ filter...
The advantages of using fresh water in cooling loops include:
  • Greatly reduced maintenance [eliminated really...] on the cooling water pumps and loops with consequent longer lifespan of those components [fresh vs. salt water]
  • Fewer open through-hull valves
  • Reverse-cycle heat [more efficient than resistance heat] works when it otherwise wouldn't when in cooler raw water temperatures
Some disadvantages are:
  • Coolant loops that were initially used with raw water need to be hyper cleaned/sanitized before switching to potable water [if the dedicated tank is also a back-up potable tank...]
    • If installing new there is no problem connecting to potable water tankage...
  • The potable tank used for these coolant loops is now 'emergency' only back-up for potable water— or we need to remember to turn off the refrigeration water cooling loop, and not use the A/C heat pump[s] 
    • We placed a check list next to water tank selector valve as a reminder
To keep the water fresh in this potable water tank used for recirculating cooling water, we routinely pull water from, and immediately refresh this tank when doing laundry while running the watermaker or when at a dock.

This set-up works well for us, and has the added benefit of saving kind souls everywhere from feeling compelled to urgently inform us our bilge pump is running continuously... [Our raw water cooling discharge is above the waterline...]

Can you think of other advantages or disadvantages to this approach?  It has been working well on our boat for years...


Related Posts and Resources:

May 22, 2016

Air Conditioning? [Living on a boat in hot weather... Updated Jun-2019]

We occasionally participate in various boating forums. [See our Some Forums We Read sidebar for links...]

Some of those topics may be relevant here, so sometimes we repost to our blog for reference.


The following may be one of those cases. To accommodate our non-boating blog readers, add additional detail, and/or just cause more confusion, I sometimes add some additional {information and links} to the original forum post, below.


Related Posts:
______________________

Link to original forum post [28-Dec-2015]


Re: Novice air conditioning question

Quote:
Originally Posted by pwilletts View Post
it seems we cannot live w/o air conditioning...I see that a lot of boats have it but not many have a genset to run it offshore.. would prefer not to use the Honda solution...what type of electrical set up will power AC w/o a genset..I assume it involves a big alternator/ big inverter and isolated switching??
PWilletts,

From your phrasing, I'm assuming shore power is not regularly available to you in your current boating lifestyle. Therefore I suspect you would need a generator if you don't want to prematurely wear out your primary engine charging batteries. [Unless you are motoring most of the time anyway...]

But I say this based upon how our boat is set up- which I'll share here for perspective on a thoroughly tested and proven setup:

The previous owners used our boat in the tropics for 15 years and therefore installed 3 independently controlled and regulated air conditioners [A/C: 9k BTU fore cabin, 18k BTU pilothouse, and 18k BTU in the master cabin. All are raw fresh water cooled using a single pump and plumbing circuit.]


Since the A/C units each have a dedicated circuit breaker and thermostat, we can run 1, 2, or all 3 as needed. [Note: when at the dock in winter we use them for heat since our current hydro electric power rates are cheaper than putting hours on our generator or Esbar diesel heater...]

Using shore power, running all 3 A/C units requires a 50 amp [or two properly paralleled 30AMP services] 115VAC [split 230VAC feed] to handle the A/C load as well as the normal boat loads [water heater, battery charger, etc.] A 6.5kw generator would also handle them and the boat, but we have a 10kw generator instead. [We were told it cost the same as the 6.5 at the time the previous owner's installed it...]

Back to your question: Could we run one of these A/C units at a time from our 2800 Watt 115VAC/125A 12VDC inverter charger? Yes. [On paper anyway- I have never had the need to attempt it...] Our 900 AH 12VDC house bank would likely handle it for a few hours. However, the energy/time required to recharge the batteries outweighs the benefits for me. Therefore we choose to run the generator when away from shore power when A/C is needed, and let it take care of other needs during that run period. [Charge batts, etc.]

Even though the need for A/C is rare where we currently cruise [55N-61N] occasionally we do exercising the units on those hot days when the pilothouse [AKA solarium] starts climbing through the mid-90s °F due to the sun. [Even with all hatches open and fans running- including a hatch exhaust fan...]

Running the A/C is also great for quickly drying out [dehumidifying] the boat when needed... [We use our dehumidifier to dry the boat as needed when A/C is not really necessary...]

I don't mind running our generator as it is very quiet and surprisingly fuel efficient. [Fisher-Panda running a 3 cyl Kubota diesel.] Yes, we can hear the low hum of the generator in the pilot house, but the blower from the AC on high drowns that out.

And outside our split exhaust arrangement makes it difficult to tell if it is running when we are outside unless one wanders over to the exhaust area and lean over to hear it blowing bubbles...

Any neighbors would never know it was running... but neighbors are rare for us... We have had kayakers approach and not realize they were approaching the running gen exhaust until they were within ~10 feet of the boat...

I hope this helps provide some prospective from another vessel's point of view.